Bläddra i källkod

IB/ehca: Fix static rate regression

Wrong choice of port number caused modify_qp() to fail -- fixed.

Signed-off-by: Joachim Fenkes <fenkes@de.ibm.com>
Signed-off-by: Roland Dreier <rolandd@cisco.com>
Joachim Fenkes 17 år sedan
förälder
incheckning
3fe2ed344d
1 ändrade filer med 2 tillägg och 2 borttagningar
  1. 2 2
      drivers/infiniband/hw/ehca/ehca_qp.c

+ 2 - 2
drivers/infiniband/hw/ehca/ehca_qp.c

@@ -1203,7 +1203,7 @@ static int internal_modify_qp(struct ib_qp *ibqp,
 		mqpcb->service_level = attr->ah_attr.sl;
 		update_mask |= EHCA_BMASK_SET(MQPCB_MASK_SERVICE_LEVEL, 1);
 
-		if (ehca_calc_ipd(shca, my_qp->init_attr.port_num,
+		if (ehca_calc_ipd(shca, mqpcb->prim_phys_port,
 				  attr->ah_attr.static_rate,
 				  &mqpcb->max_static_rate)) {
 			ret = -EINVAL;
@@ -1302,7 +1302,7 @@ static int internal_modify_qp(struct ib_qp *ibqp,
 		mqpcb->source_path_bits_al = attr->alt_ah_attr.src_path_bits;
 		mqpcb->service_level_al = attr->alt_ah_attr.sl;
 
-		if (ehca_calc_ipd(shca, my_qp->init_attr.port_num,
+		if (ehca_calc_ipd(shca, mqpcb->alt_phys_port,
 				  attr->alt_ah_attr.static_rate,
 				  &mqpcb->max_static_rate_al)) {
 			ret = -EINVAL;