Browse Source

hwmon: (acpi_power_meter) Fix acpi_bus_get_device() return value check

Since acpi_bus_get_device() returns plain int and not acpi_status,
ACPI_FAILURE() should not be used for checking its return value.  Fix
that.

Signed-off-by: Yijing Wang <wangyijing@huawei.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Yijing Wang 11 năm trước cách đây
mục cha
commit
3a4cbc1906
1 tập tin đã thay đổi với 2 bổ sung3 xóa
  1. 2 3
      drivers/hwmon/acpi_power_meter.c

+ 2 - 3
drivers/hwmon/acpi_power_meter.c

@@ -602,9 +602,8 @@ static int read_domain_devices(struct acpi_power_meter_resource *resource)
 
 		/* Create a symlink to domain objects */
 		resource->domain_devices[i] = NULL;
-		status = acpi_bus_get_device(element->reference.handle,
-					     &resource->domain_devices[i]);
-		if (ACPI_FAILURE(status))
+		if (acpi_bus_get_device(element->reference.handle,
+					&resource->domain_devices[i]))
 			continue;
 
 		obj = resource->domain_devices[i];