Generic Thermal Sysfs driver How To
|
|
|
-=========================
|
|
|
+===================================
|
|
|
|
|
|
Written by Sujith Thomas <sujith.thomas@intel.com>, Zhang Rui <rui.zhang@intel.com>
|
|
|
|
|
@@ -10,20 +10,20 @@ Copyright (c) 2008 Intel Corporation
|
|
|
|
|
|
0. Introduction
|
|
|
|
|
|
-The generic thermal sysfs provides a set of interfaces for thermal zone devices (sensors)
|
|
|
-and thermal cooling devices (fan, processor...) to register with the thermal management
|
|
|
-solution and to be a part of it.
|
|
|
+The generic thermal sysfs provides a set of interfaces for thermal zone
|
|
|
+devices (sensors) and thermal cooling devices (fan, processor...) to register
|
|
|
+with the thermal management solution and to be a part of it.
|
|
|
|
|
|
-This how-to focuses on enabling new thermal zone and cooling devices to participate
|
|
|
-in thermal management.
|
|
|
-This solution is platform independent and any type of thermal zone devices and
|
|
|
-cooling devices should be able to make use of the infrastructure.
|
|
|
+This how-to focuses on enabling new thermal zone and cooling devices to
|
|
|
+participate in thermal management.
|
|
|
+This solution is platform independent and any type of thermal zone devices
|
|
|
+and cooling devices should be able to make use of the infrastructure.
|
|
|
|
|
|
-The main task of the thermal sysfs driver is to expose thermal zone attributes as well
|
|
|
-as cooling device attributes to the user space.
|
|
|
-An intelligent thermal management application can make decisions based on inputs
|
|
|
-from thermal zone attributes (the current temperature and trip point temperature)
|
|
|
-and throttle appropriate devices.
|
|
|
+The main task of the thermal sysfs driver is to expose thermal zone attributes
|
|
|
+as well as cooling device attributes to the user space.
|
|
|
+An intelligent thermal management application can make decisions based on
|
|
|
+inputs from thermal zone attributes (the current temperature and trip point
|
|
|
+temperature) and throttle appropriate devices.
|
|
|
|
|
|
[0-*] denotes any positive number starting from 0
|
|
|
[1-*] denotes any positive number starting from 1
|
|
@@ -31,77 +31,77 @@ and throttle appropriate devices.
|
|
|
1. thermal sysfs driver interface functions
|
|
|
|
|
|
1.1 thermal zone device interface
|
|
|
-1.1.1 struct thermal_zone_device *thermal_zone_device_register(char *name, int trips,
|
|
|
- void *devdata, struct thermal_zone_device_ops *ops)
|
|
|
-
|
|
|
- This interface function adds a new thermal zone device (sensor) to
|
|
|
- /sys/class/thermal folder as thermal_zone[0-*].
|
|
|
- It tries to bind all the thermal cooling devices registered at the same time.
|
|
|
-
|
|
|
- name: the thermal zone name.
|
|
|
- trips: the total number of trip points this thermal zone supports.
|
|
|
- devdata: device private data
|
|
|
- ops: thermal zone device call-backs.
|
|
|
- .bind: bind the thermal zone device with a thermal cooling device.
|
|
|
- .unbind: unbind the thermal zone device with a thermal cooling device.
|
|
|
- .get_temp: get the current temperature of the thermal zone.
|
|
|
- .get_mode: get the current mode (user/kernel) of the thermal zone.
|
|
|
- "kernel" means thermal management is done in kernel.
|
|
|
- "user" will prevent kernel thermal driver actions upon trip points
|
|
|
- so that user applications can take charge of thermal management.
|
|
|
- .set_mode: set the mode (user/kernel) of the thermal zone.
|
|
|
- .get_trip_type: get the type of certain trip point.
|
|
|
- .get_trip_temp: get the temperature above which the certain trip point
|
|
|
- will be fired.
|
|
|
+1.1.1 struct thermal_zone_device *thermal_zone_device_register(char *name,
|
|
|
+ int trips, void *devdata, struct thermal_zone_device_ops *ops)
|
|
|
+
|
|
|
+ This interface function adds a new thermal zone device (sensor) to
|
|
|
+ /sys/class/thermal folder as thermal_zone[0-*]. It tries to bind all the
|
|
|
+ thermal cooling devices registered at the same time.
|
|
|
+
|
|
|
+ name: the thermal zone name.
|
|
|
+ trips: the total number of trip points this thermal zone supports.
|
|
|
+ devdata: device private data
|
|
|
+ ops: thermal zone device call-backs.
|
|
|
+ .bind: bind the thermal zone device with a thermal cooling device.
|
|
|
+ .unbind: unbind the thermal zone device with a thermal cooling device.
|
|
|
+ .get_temp: get the current temperature of the thermal zone.
|
|
|
+ .get_mode: get the current mode (user/kernel) of the thermal zone.
|
|
|
+ - "kernel" means thermal management is done in kernel.
|
|
|
+ - "user" will prevent kernel thermal driver actions upon trip points
|
|
|
+ so that user applications can take charge of thermal management.
|
|
|
+ .set_mode: set the mode (user/kernel) of the thermal zone.
|
|
|
+ .get_trip_type: get the type of certain trip point.
|
|
|
+ .get_trip_temp: get the temperature above which the certain trip point
|
|
|
+ will be fired.
|
|
|
|
|
|
1.1.2 void thermal_zone_device_unregister(struct thermal_zone_device *tz)
|
|
|
|
|
|
- This interface function removes the thermal zone device.
|
|
|
- It deletes the corresponding entry form /sys/class/thermal folder and unbind all
|
|
|
- the thermal cooling devices it uses.
|
|
|
+ This interface function removes the thermal zone device.
|
|
|
+ It deletes the corresponding entry form /sys/class/thermal folder and
|
|
|
+ unbind all the thermal cooling devices it uses.
|
|
|
|
|
|
1.2 thermal cooling device interface
|
|
|
1.2.1 struct thermal_cooling_device *thermal_cooling_device_register(char *name,
|
|
|
- void *devdata, struct thermal_cooling_device_ops *)
|
|
|
-
|
|
|
- This interface function adds a new thermal cooling device (fan/processor/...) to
|
|
|
- /sys/class/thermal/ folder as cooling_device[0-*].
|
|
|
- It tries to bind itself to all the thermal zone devices register at the same time.
|
|
|
- name: the cooling device name.
|
|
|
- devdata: device private data.
|
|
|
- ops: thermal cooling devices call-backs.
|
|
|
- .get_max_state: get the Maximum throttle state of the cooling device.
|
|
|
- .get_cur_state: get the Current throttle state of the cooling device.
|
|
|
- .set_cur_state: set the Current throttle state of the cooling device.
|
|
|
+ void *devdata, struct thermal_cooling_device_ops *)
|
|
|
+
|
|
|
+ This interface function adds a new thermal cooling device (fan/processor/...)
|
|
|
+ to /sys/class/thermal/ folder as cooling_device[0-*]. It tries to bind itself
|
|
|
+ to all the thermal zone devices register at the same time.
|
|
|
+ name: the cooling device name.
|
|
|
+ devdata: device private data.
|
|
|
+ ops: thermal cooling devices call-backs.
|
|
|
+ .get_max_state: get the Maximum throttle state of the cooling device.
|
|
|
+ .get_cur_state: get the Current throttle state of the cooling device.
|
|
|
+ .set_cur_state: set the Current throttle state of the cooling device.
|
|
|
|
|
|
1.2.2 void thermal_cooling_device_unregister(struct thermal_cooling_device *cdev)
|
|
|
|
|
|
- This interface function remove the thermal cooling device.
|
|
|
- It deletes the corresponding entry form /sys/class/thermal folder and unbind
|
|
|
- itself from all the thermal zone devices using it.
|
|
|
+ This interface function remove the thermal cooling device.
|
|
|
+ It deletes the corresponding entry form /sys/class/thermal folder and
|
|
|
+ unbind itself from all the thermal zone devices using it.
|
|
|
|
|
|
1.3 interface for binding a thermal zone device with a thermal cooling device
|
|
|
1.3.1 int thermal_zone_bind_cooling_device(struct thermal_zone_device *tz,
|
|
|
- int trip, struct thermal_cooling_device *cdev);
|
|
|
+ int trip, struct thermal_cooling_device *cdev);
|
|
|
|
|
|
- This interface function bind a thermal cooling device to the certain trip point
|
|
|
- of a thermal zone device.
|
|
|
- This function is usually called in the thermal zone device .bind callback.
|
|
|
- tz: the thermal zone device
|
|
|
- cdev: thermal cooling device
|
|
|
- trip: indicates which trip point the cooling devices is associated with
|
|
|
- in this thermal zone.
|
|
|
+ This interface function bind a thermal cooling device to the certain trip
|
|
|
+ point of a thermal zone device.
|
|
|
+ This function is usually called in the thermal zone device .bind callback.
|
|
|
+ tz: the thermal zone device
|
|
|
+ cdev: thermal cooling device
|
|
|
+ trip: indicates which trip point the cooling devices is associated with
|
|
|
+ in this thermal zone.
|
|
|
|
|
|
1.3.2 int thermal_zone_unbind_cooling_device(struct thermal_zone_device *tz,
|
|
|
- int trip, struct thermal_cooling_device *cdev);
|
|
|
+ int trip, struct thermal_cooling_device *cdev);
|
|
|
|
|
|
- This interface function unbind a thermal cooling device from the certain trip point
|
|
|
- of a thermal zone device.
|
|
|
- This function is usually called in the thermal zone device .unbind callback.
|
|
|
- tz: the thermal zone device
|
|
|
- cdev: thermal cooling device
|
|
|
- trip: indicates which trip point the cooling devices is associated with
|
|
|
- in this thermal zone.
|
|
|
+ This interface function unbind a thermal cooling device from the certain
|
|
|
+ trip point of a thermal zone device. This function is usually called in
|
|
|
+ the thermal zone device .unbind callback.
|
|
|
+ tz: the thermal zone device
|
|
|
+ cdev: thermal cooling device
|
|
|
+ trip: indicates which trip point the cooling devices is associated with
|
|
|
+ in this thermal zone.
|
|
|
|
|
|
2. sysfs attributes structure
|
|
|
|
|
@@ -114,153 +114,157 @@ if hwmon is compiled in or built as a module.
|
|
|
|
|
|
Thermal zone device sys I/F, created once it's registered:
|
|
|
/sys/class/thermal/thermal_zone[0-*]:
|
|
|
- |-----type: Type of the thermal zone
|
|
|
- |-----temp: Current temperature
|
|
|
- |-----mode: Working mode of the thermal zone
|
|
|
- |-----trip_point_[0-*]_temp: Trip point temperature
|
|
|
- |-----trip_point_[0-*]_type: Trip point type
|
|
|
+ |---type: Type of the thermal zone
|
|
|
+ |---temp: Current temperature
|
|
|
+ |---mode: Working mode of the thermal zone
|
|
|
+ |---trip_point_[0-*]_temp: Trip point temperature
|
|
|
+ |---trip_point_[0-*]_type: Trip point type
|
|
|
|
|
|
Thermal cooling device sys I/F, created once it's registered:
|
|
|
/sys/class/thermal/cooling_device[0-*]:
|
|
|
- |-----type : Type of the cooling device(processor/fan/...)
|
|
|
- |-----max_state: Maximum cooling state of the cooling device
|
|
|
- |-----cur_state: Current cooling state of the cooling device
|
|
|
+ |---type: Type of the cooling device(processor/fan/...)
|
|
|
+ |---max_state: Maximum cooling state of the cooling device
|
|
|
+ |---cur_state: Current cooling state of the cooling device
|
|
|
|
|
|
|
|
|
-These two dynamic attributes are created/removed in pairs.
|
|
|
-They represent the relationship between a thermal zone and its associated cooling device.
|
|
|
-They are created/removed for each
|
|
|
-thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device successful execution.
|
|
|
+Then next two dynamic attributes are created/removed in pairs. They represent
|
|
|
+the relationship between a thermal zone and its associated cooling device.
|
|
|
+They are created/removed for each successful execution of
|
|
|
+thermal_zone_bind_cooling_device/thermal_zone_unbind_cooling_device.
|
|
|
|
|
|
-/sys/class/thermal/thermal_zone[0-*]
|
|
|
- |-----cdev[0-*]: The [0-*]th cooling device in the current thermal zone
|
|
|
- |-----cdev[0-*]_trip_point: Trip point that cdev[0-*] is associated with
|
|
|
+/sys/class/thermal/thermal_zone[0-*]:
|
|
|
+ |---cdev[0-*]: [0-*]th cooling device in current thermal zone
|
|
|
+ |---cdev[0-*]_trip_point: Trip point that cdev[0-*] is associated with
|
|
|
|
|
|
Besides the thermal zone device sysfs I/F and cooling device sysfs I/F,
|
|
|
-the generic thermal driver also creates a hwmon sysfs I/F for each _type_ of
|
|
|
-thermal zone device. E.g. the generic thermal driver registers one hwmon class device
|
|
|
-and build the associated hwmon sysfs I/F for all the registered ACPI thermal zones.
|
|
|
+the generic thermal driver also creates a hwmon sysfs I/F for each _type_
|
|
|
+of thermal zone device. E.g. the generic thermal driver registers one hwmon
|
|
|
+class device and build the associated hwmon sysfs I/F for all the registered
|
|
|
+ACPI thermal zones.
|
|
|
+
|
|
|
/sys/class/hwmon/hwmon[0-*]:
|
|
|
- |-----name: The type of the thermal zone devices.
|
|
|
- |-----temp[1-*]_input: The current temperature of thermal zone [1-*].
|
|
|
- |-----temp[1-*]_critical: The critical trip point of thermal zone [1-*].
|
|
|
+ |---name: The type of the thermal zone devices
|
|
|
+ |---temp[1-*]_input: The current temperature of thermal zone [1-*]
|
|
|
+ |---temp[1-*]_critical: The critical trip point of thermal zone [1-*]
|
|
|
+
|
|
|
Please read Documentation/hwmon/sysfs-interface for additional information.
|
|
|
|
|
|
***************************
|
|
|
* Thermal zone attributes *
|
|
|
***************************
|
|
|
|
|
|
-type Strings which represent the thermal zone type.
|
|
|
- This is given by thermal zone driver as part of registration.
|
|
|
- Eg: "acpitz" indicates it's an ACPI thermal device.
|
|
|
- In order to keep it consistent with hwmon sys attribute,
|
|
|
- this should be a short, lowercase string,
|
|
|
- not containing spaces nor dashes.
|
|
|
- RO
|
|
|
- Required
|
|
|
-
|
|
|
-temp Current temperature as reported by thermal zone (sensor)
|
|
|
- Unit: millidegree Celsius
|
|
|
- RO
|
|
|
- Required
|
|
|
-
|
|
|
-mode One of the predefined values in [kernel, user]
|
|
|
- This file gives information about the algorithm
|
|
|
- that is currently managing the thermal zone.
|
|
|
- It can be either default kernel based algorithm
|
|
|
- or user space application.
|
|
|
- RW
|
|
|
- Optional
|
|
|
- kernel = Thermal management in kernel thermal zone driver.
|
|
|
- user = Preventing kernel thermal zone driver actions upon
|
|
|
- trip points so that user application can take full
|
|
|
- charge of the thermal management.
|
|
|
-
|
|
|
-trip_point_[0-*]_temp The temperature above which trip point will be fired
|
|
|
- Unit: millidegree Celsius
|
|
|
- RO
|
|
|
- Optional
|
|
|
-
|
|
|
-trip_point_[0-*]_type Strings which indicate the type of the trip point
|
|
|
- E.g. it can be one of critical, hot, passive,
|
|
|
- active[0-*] for ACPI thermal zone.
|
|
|
- RO
|
|
|
- Optional
|
|
|
-
|
|
|
-cdev[0-*] Sysfs link to the thermal cooling device node where the sys I/F
|
|
|
- for cooling device throttling control represents.
|
|
|
- RO
|
|
|
- Optional
|
|
|
-
|
|
|
-cdev[0-*]_trip_point The trip point with which cdev[0-*] is associated in this thermal zone
|
|
|
- -1 means the cooling device is not associated with any trip point.
|
|
|
- RO
|
|
|
- Optional
|
|
|
-
|
|
|
-******************************
|
|
|
-* Cooling device attributes *
|
|
|
-******************************
|
|
|
-
|
|
|
-type String which represents the type of device
|
|
|
- eg: For generic ACPI: this should be "Fan",
|
|
|
- "Processor" or "LCD"
|
|
|
- eg. For memory controller device on intel_menlow platform:
|
|
|
- this should be "Memory controller"
|
|
|
- RO
|
|
|
- Required
|
|
|
-
|
|
|
-max_state The maximum permissible cooling state of this cooling device.
|
|
|
- RO
|
|
|
- Required
|
|
|
-
|
|
|
-cur_state The current cooling state of this cooling device.
|
|
|
- the value can any integer numbers between 0 and max_state,
|
|
|
- cur_state == 0 means no cooling
|
|
|
- cur_state == max_state means the maximum cooling.
|
|
|
- RW
|
|
|
- Required
|
|
|
+type
|
|
|
+ Strings which represent the thermal zone type.
|
|
|
+ This is given by thermal zone driver as part of registration.
|
|
|
+ E.g: "acpitz" indicates it's an ACPI thermal device.
|
|
|
+ In order to keep it consistent with hwmon sys attribute; this should
|
|
|
+ be a short, lowercase string, not containing spaces nor dashes.
|
|
|
+ RO, Required
|
|
|
+
|
|
|
+temp
|
|
|
+ Current temperature as reported by thermal zone (sensor).
|
|
|
+ Unit: millidegree Celsius
|
|
|
+ RO, Required
|
|
|
+
|
|
|
+mode
|
|
|
+ One of the predefined values in [kernel, user].
|
|
|
+ This file gives information about the algorithm that is currently
|
|
|
+ managing the thermal zone. It can be either default kernel based
|
|
|
+ algorithm or user space application.
|
|
|
+ kernel = Thermal management in kernel thermal zone driver.
|
|
|
+ user = Preventing kernel thermal zone driver actions upon
|
|
|
+ trip points so that user application can take full
|
|
|
+ charge of the thermal management.
|
|
|
+ RW, Optional
|
|
|
+
|
|
|
+trip_point_[0-*]_temp
|
|
|
+ The temperature above which trip point will be fired.
|
|
|
+ Unit: millidegree Celsius
|
|
|
+ RO, Optional
|
|
|
+
|
|
|
+trip_point_[0-*]_type
|
|
|
+ Strings which indicate the type of the trip point.
|
|
|
+ E.g. it can be one of critical, hot, passive, active[0-*] for ACPI
|
|
|
+ thermal zone.
|
|
|
+ RO, Optional
|
|
|
+
|
|
|
+cdev[0-*]
|
|
|
+ Sysfs link to the thermal cooling device node where the sys I/F
|
|
|
+ for cooling device throttling control represents.
|
|
|
+ RO, Optional
|
|
|
+
|
|
|
+cdev[0-*]_trip_point
|
|
|
+ The trip point with which cdev[0-*] is associated in this thermal
|
|
|
+ zone; -1 means the cooling device is not associated with any trip
|
|
|
+ point.
|
|
|
+ RO, Optional
|
|
|
+
|
|
|
+*****************************
|
|
|
+* Cooling device attributes *
|
|
|
+*****************************
|
|
|
+
|
|
|
+type
|
|
|
+ String which represents the type of device, e.g:
|
|
|
+ - for generic ACPI: should be "Fan", "Processor" or "LCD"
|
|
|
+ - for memory controller device on intel_menlow platform:
|
|
|
+ should be "Memory controller".
|
|
|
+ RO, Required
|
|
|
+
|
|
|
+max_state
|
|
|
+ The maximum permissible cooling state of this cooling device.
|
|
|
+ RO, Required
|
|
|
+
|
|
|
+cur_state
|
|
|
+ The current cooling state of this cooling device.
|
|
|
+ The value can any integer numbers between 0 and max_state:
|
|
|
+ - cur_state == 0 means no cooling
|
|
|
+ - cur_state == max_state means the maximum cooling.
|
|
|
+ RW, Required
|
|
|
|
|
|
3. A simple implementation
|
|
|
|
|
|
-ACPI thermal zone may support multiple trip points like critical/hot/passive/active.
|
|
|
-If an ACPI thermal zone supports critical, passive, active[0] and active[1] at the same time,
|
|
|
-it may register itself as a thermal_zone_device (thermal_zone1) with 4 trip points in all.
|
|
|
-It has one processor and one fan, which are both registered as thermal_cooling_device.
|
|
|
-If the processor is listed in _PSL method, and the fan is listed in _AL0 method,
|
|
|
-the sys I/F structure will be built like this:
|
|
|
+ACPI thermal zone may support multiple trip points like critical, hot,
|
|
|
+passive, active. If an ACPI thermal zone supports critical, passive,
|
|
|
+active[0] and active[1] at the same time, it may register itself as a
|
|
|
+thermal_zone_device (thermal_zone1) with 4 trip points in all.
|
|
|
+It has one processor and one fan, which are both registered as
|
|
|
+thermal_cooling_device.
|
|
|
+
|
|
|
+If the processor is listed in _PSL method, and the fan is listed in _AL0
|
|
|
+method, the sys I/F structure will be built like this:
|
|
|
|
|
|
/sys/class/thermal:
|
|
|
|
|
|
|thermal_zone1:
|
|
|
- |-----type: acpitz
|
|
|
- |-----temp: 37000
|
|
|
- |-----mode: kernel
|
|
|
- |-----trip_point_0_temp: 100000
|
|
|
- |-----trip_point_0_type: critical
|
|
|
- |-----trip_point_1_temp: 80000
|
|
|
- |-----trip_point_1_type: passive
|
|
|
- |-----trip_point_2_temp: 70000
|
|
|
- |-----trip_point_2_type: active0
|
|
|
- |-----trip_point_3_temp: 60000
|
|
|
- |-----trip_point_3_type: active1
|
|
|
- |-----cdev0: --->/sys/class/thermal/cooling_device0
|
|
|
- |-----cdev0_trip_point: 1 /* cdev0 can be used for passive */
|
|
|
- |-----cdev1: --->/sys/class/thermal/cooling_device3
|
|
|
- |-----cdev1_trip_point: 2 /* cdev1 can be used for active[0]*/
|
|
|
+ |---type: acpitz
|
|
|
+ |---temp: 37000
|
|
|
+ |---mode: kernel
|
|
|
+ |---trip_point_0_temp: 100000
|
|
|
+ |---trip_point_0_type: critical
|
|
|
+ |---trip_point_1_temp: 80000
|
|
|
+ |---trip_point_1_type: passive
|
|
|
+ |---trip_point_2_temp: 70000
|
|
|
+ |---trip_point_2_type: active0
|
|
|
+ |---trip_point_3_temp: 60000
|
|
|
+ |---trip_point_3_type: active1
|
|
|
+ |---cdev0: --->/sys/class/thermal/cooling_device0
|
|
|
+ |---cdev0_trip_point: 1 /* cdev0 can be used for passive */
|
|
|
+ |---cdev1: --->/sys/class/thermal/cooling_device3
|
|
|
+ |---cdev1_trip_point: 2 /* cdev1 can be used for active[0]*/
|
|
|
|
|
|
|cooling_device0:
|
|
|
- |-----type: Processor
|
|
|
- |-----max_state: 8
|
|
|
- |-----cur_state: 0
|
|
|
+ |---type: Processor
|
|
|
+ |---max_state: 8
|
|
|
+ |---cur_state: 0
|
|
|
|
|
|
|cooling_device3:
|
|
|
- |-----type: Fan
|
|
|
- |-----max_state: 2
|
|
|
- |-----cur_state: 0
|
|
|
+ |---type: Fan
|
|
|
+ |---max_state: 2
|
|
|
+ |---cur_state: 0
|
|
|
|
|
|
/sys/class/hwmon:
|
|
|
|
|
|
|hwmon0:
|
|
|
- |-----name: acpitz
|
|
|
- |-----temp1_input: 37000
|
|
|
- |-----temp1_crit: 100000
|
|
|
+ |---name: acpitz
|
|
|
+ |---temp1_input: 37000
|
|
|
+ |---temp1_crit: 100000
|