[ALSA] ice1712 - Fix wordclock status on Delta1010LT

Modules: ICE1712 driver

I posted this patch to bug 1806 a while back, and have been awaiting a
reply or commit.  It currently reports the Locked/No Signal text
backwards in envy24control, since i was using an older version of
envy24control when I wrote the original code.  The Locked/No Signal test
was recently reversed in envy24control cvs, so the test in my code needs
to be reversed as well.  Here is the patch, once again.

Signed-off-by: Takashi Iwai <tiwai@suse.de>
Doug McLain 19 年之前
父节点
当前提交
381e3cda68
共有 1 个文件被更改,包括 1 次插入1 次删除
  1. 1 1
      sound/pci/ice1712/delta.c

+ 1 - 1
sound/pci/ice1712/delta.c

@@ -412,7 +412,7 @@ int snd_ice1712_delta1010lt_wordclock_status_get(struct snd_kcontrol *kcontrol,
 	if (snd_i2c_sendbytes(ice->cs8427, &reg, 1) != 1)
 		snd_printk(KERN_ERR "unable to send register 0x%x byte to CS8427\n", reg);
 	snd_i2c_readbytes(ice->cs8427, &reg, 1);
-	ucontrol->value.integer.value[0] = (reg ? 0 : 1);
+	ucontrol->value.integer.value[0] = (reg ? 1 : 0);
 	return 0;
 }