@@ -0,0 +1,243 @@
|
|
|
+/*
|
|
|
+ * Copyright © 2007 Anton Vorontsov <cbou@mail.ru>
|
|
|
+ * Copyright © 2007 Eugeny Boger <eugenyboger@dgap.mipt.ru>
|
|
|
+ *
|
|
|
+ * Author: Eugeny Boger <eugenyboger@dgap.mipt.ru>
|
|
|
+ *
|
|
|
+ * Use consistent with the GNU GPL is permitted,
|
|
|
+ * provided that this copyright notice is
|
|
|
+ * preserved in its entirety in all copies and derived works.
|
|
|
+ */
|
|
|
+
|
|
|
+#include <linux/module.h>
|
|
|
+#include <linux/power_supply.h>
|
|
|
+#include <linux/apm-emulation.h>
|
|
|
+
|
|
|
+#define PSY_PROP(psy, prop, val) psy->get_property(psy, \
|
|
|
+ POWER_SUPPLY_PROP_##prop, val)
|
|
|
+
|
|
|
+#define _MPSY_PROP(prop, val) main_battery->get_property(main_battery, \
|
|
|
+ prop, val)
|
|
|
+
|
|
|
+#define MPSY_PROP(prop, val) _MPSY_PROP(POWER_SUPPLY_PROP_##prop, val)
|
|
|
+
|
|
|
+static struct power_supply *main_battery;
|
|
|
+
|
|
|
+static void find_main_battery(void)
|
|
|
+{
|
|
|
+ struct device *dev;
|
|
|
+ struct power_supply *bat, *batm;
|
|
|
+ union power_supply_propval full;
|
|
|
+ int max_charge = 0;
|
|
|
+
|
|
|
+ main_battery = NULL;
|
|
|
+ batm = NULL;
|
|
|
+ list_for_each_entry(dev, &power_supply_class->devices, node) {
|
|
|
+ bat = dev_get_drvdata(dev);
|
|
|
+ /* If none of battery devices cantains 'use_for_apm' flag,
|
|
|
+ choice one with maximum design charge */
|
|
|
+ if (!PSY_PROP(bat, CHARGE_FULL_DESIGN, &full)) {
|
|
|
+ if (full.intval > max_charge) {
|
|
|
+ batm = bat;
|
|
|
+ max_charge = full.intval;
|
|
|
+ }
|
|
|
+ }
|
|
|
+
|
|
|
+ if (bat->use_for_apm)
|
|
|
+ main_battery = bat;
|
|
|
+ }
|
|
|
+ if (!main_battery)
|
|
|
+ main_battery = batm;
|
|
|
+
|
|
|
+ return;
|
|
|
+}
|
|
|
+
|
|
|
+static int calculate_time(int status)
|
|
|
+{
|
|
|
+ union power_supply_propval charge_full, charge_empty;
|
|
|
+ union power_supply_propval charge, I;
|
|
|
+
|
|
|
+ if (MPSY_PROP(CHARGE_FULL, &charge_full)) {
|
|
|
+ /* if battery can't report this property, use design value */
|
|
|
+ if (MPSY_PROP(CHARGE_FULL_DESIGN, &charge_full))
|
|
|
+ return -1;
|
|
|
+ }
|
|
|
+
|
|
|
+ if (MPSY_PROP(CHARGE_EMPTY, &charge_empty)) {
|
|
|
+ /* if battery can't report this property, use design value */
|
|
|
+ if (MPSY_PROP(CHARGE_EMPTY_DESIGN, &charge_empty))
|
|
|
+ charge_empty.intval = 0;
|
|
|
+ }
|
|
|
+
|
|
|
+ if (MPSY_PROP(CHARGE_AVG, &charge)) {
|
|
|
+ /* if battery can't report average value, use momentary */
|
|
|
+ if (MPSY_PROP(CHARGE_NOW, &charge))
|
|
|
+ return -1;
|
|
|
+ }
|
|
|
+
|
|
|
+ if (MPSY_PROP(CURRENT_AVG, &I)) {
|
|
|
+ /* if battery can't report average value, use momentary */
|
|
|
+ if (MPSY_PROP(CURRENT_NOW, &I))
|
|
|
+ return -1;
|
|
|
+ }
|
|
|
+
|
|
|
+ if (status == POWER_SUPPLY_STATUS_CHARGING)
|
|
|
+ return ((charge.intval - charge_full.intval) * 60L) /
|
|
|
+ I.intval;
|
|
|
+ else
|
|
|
+ return -((charge.intval - charge_empty.intval) * 60L) /
|
|
|
+ I.intval;
|
|
|
+}
|
|
|
+
|
|
|
+static int calculate_capacity(int using_charge)
|
|
|
+{
|
|
|
+ enum power_supply_property full_prop, empty_prop;
|
|
|
+ enum power_supply_property full_design_prop, empty_design_prop;
|
|
|
+ enum power_supply_property now_prop, avg_prop;
|
|
|
+ union power_supply_propval empty, full, cur;
|
|
|
+ int ret;
|
|
|
+
|
|
|
+ if (using_charge) {
|
|
|
+ full_prop = POWER_SUPPLY_PROP_CHARGE_FULL;
|
|
|
+ empty_prop = POWER_SUPPLY_PROP_CHARGE_EMPTY;
|
|
|
+ full_design_prop = POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN;
|
|
|
+ empty_design_prop = POWER_SUPPLY_PROP_CHARGE_EMPTY_DESIGN;
|
|
|
+ now_prop = POWER_SUPPLY_PROP_CHARGE_NOW;
|
|
|
+ avg_prop = POWER_SUPPLY_PROP_CHARGE_AVG;
|
|
|
+ } else {
|
|
|
+ full_prop = POWER_SUPPLY_PROP_ENERGY_FULL;
|
|
|
+ empty_prop = POWER_SUPPLY_PROP_ENERGY_EMPTY;
|
|
|
+ full_design_prop = POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN;
|
|
|
+ empty_design_prop = POWER_SUPPLY_PROP_ENERGY_EMPTY_DESIGN;
|
|
|
+ now_prop = POWER_SUPPLY_PROP_ENERGY_NOW;
|
|
|
+ avg_prop = POWER_SUPPLY_PROP_ENERGY_AVG;
|
|
|
+ }
|
|
|
+
|
|
|
+ if (_MPSY_PROP(full_prop, &full)) {
|
|
|
+ /* if battery can't report this property, use design value */
|
|
|
+ if (_MPSY_PROP(full_design_prop, &full))
|
|
|
+ return -1;
|
|
|
+ }
|
|
|
+
|
|
|
+ if (_MPSY_PROP(avg_prop, &cur)) {
|
|
|
+ /* if battery can't report average value, use momentary */
|
|
|
+ if (_MPSY_PROP(now_prop, &cur))
|
|
|
+ return -1;
|
|
|
+ }
|
|
|
+
|
|
|
+ if (_MPSY_PROP(empty_prop, &empty)) {
|
|
|
+ /* if battery can't report this property, use design value */
|
|
|
+ if (_MPSY_PROP(empty_design_prop, &empty))
|
|
|
+ empty.intval = 0;
|
|
|
+ }
|
|
|
+
|
|
|
+ if (full.intval - empty.intval)
|
|
|
+ ret = ((cur.intval - empty.intval) * 100L) /
|
|
|
+ (full.intval - empty.intval);
|
|
|
+ else
|
|
|
+ return -1;
|
|
|
+
|
|
|
+ if (ret > 100)
|
|
|
+ return 100;
|
|
|
+ else if (ret < 0)
|
|
|
+ return 0;
|
|
|
+
|
|
|
+ return ret;
|
|
|
+}
|
|
|
+
|
|
|
+static void apm_battery_apm_get_power_status(struct apm_power_info *info)
|
|
|
+{
|
|
|
+ union power_supply_propval status;
|
|
|
+ union power_supply_propval capacity, time_to_full, time_to_empty;
|
|
|
+
|
|
|
+ down(&power_supply_class->sem);
|
|
|
+ find_main_battery();
|
|
|
+ if (!main_battery) {
|
|
|
+ up(&power_supply_class->sem);
|
|
|
+ return;
|
|
|
+ }
|
|
|
+
|
|
|
+ /* status */
|
|
|
+
|
|
|
+ if (MPSY_PROP(STATUS, &status))
|
|
|
+ status.intval = POWER_SUPPLY_STATUS_UNKNOWN;
|
|
|
+
|
|
|
+ /* ac line status */
|
|
|
+
|
|
|
+ if ((status.intval == POWER_SUPPLY_STATUS_CHARGING) ||
|
|
|
+ (status.intval == POWER_SUPPLY_STATUS_NOT_CHARGING) ||
|
|
|
+ (status.intval == POWER_SUPPLY_STATUS_FULL))
|
|
|
+ info->ac_line_status = APM_AC_ONLINE;
|
|
|
+ else
|
|
|
+ info->ac_line_status = APM_AC_OFFLINE;
|
|
|
+
|
|
|
+ /* battery life (i.e. capacity, in percents) */
|
|
|
+
|
|
|
+ if (MPSY_PROP(CAPACITY, &capacity) == 0) {
|
|
|
+ info->battery_life = capacity.intval;
|
|
|
+ } else {
|
|
|
+ /* try calculate using energy */
|
|
|
+ info->battery_life = calculate_capacity(0);
|
|
|
+ /* if failed try calculate using charge instead */
|
|
|
+ if (info->battery_life == -1)
|
|
|
+ info->battery_life = calculate_capacity(1);
|
|
|
+ }
|
|
|
+
|
|
|
+ /* charging status */
|
|
|
+
|
|
|
+ if (status.intval == POWER_SUPPLY_STATUS_CHARGING) {
|
|
|
+ info->battery_status = APM_BATTERY_STATUS_CHARGING;
|
|
|
+ } else {
|
|
|
+ if (info->battery_life > 50)
|
|
|
+ info->battery_status = APM_BATTERY_STATUS_HIGH;
|
|
|
+ else if (info->battery_life > 5)
|
|
|
+ info->battery_status = APM_BATTERY_STATUS_LOW;
|
|
|
+ else
|
|
|
+ info->battery_status = APM_BATTERY_STATUS_CRITICAL;
|
|
|
+ }
|
|
|
+ info->battery_flag = info->battery_status;
|
|
|
+
|
|
|
+ /* time */
|
|
|
+
|
|
|
+ info->units = APM_UNITS_MINS;
|
|
|
+
|
|
|
+ if (status.intval == POWER_SUPPLY_STATUS_CHARGING) {
|
|
|
+ if (MPSY_PROP(TIME_TO_FULL_AVG, &time_to_full)) {
|
|
|
+ if (MPSY_PROP(TIME_TO_FULL_NOW, &time_to_full))
|
|
|
+ info->time = calculate_time(status.intval);
|
|
|
+ else
|
|
|
+ info->time = time_to_full.intval / 60;
|
|
|
+ }
|
|
|
+ } else {
|
|
|
+ if (MPSY_PROP(TIME_TO_EMPTY_AVG, &time_to_empty)) {
|
|
|
+ if (MPSY_PROP(TIME_TO_EMPTY_NOW, &time_to_empty))
|
|
|
+ info->time = calculate_time(status.intval);
|
|
|
+ else
|
|
|
+ info->time = time_to_empty.intval / 60;
|
|
|
+ }
|
|
|
+ }
|
|
|
+
|
|
|
+ up(&power_supply_class->sem);
|
|
|
+ return;
|
|
|
+}
|
|
|
+
|
|
|
+static int __init apm_battery_init(void)
|
|
|
+{
|
|
|
+ printk(KERN_INFO "APM Battery Driver\n");
|
|
|
+
|
|
|
+ apm_get_power_status = apm_battery_apm_get_power_status;
|
|
|
+ return 0;
|
|
|
+}
|
|
|
+
|
|
|
+static void __exit apm_battery_exit(void)
|
|
|
+{
|
|
|
+ apm_get_power_status = NULL;
|
|
|
+ return;
|
|
|
+}
|
|
|
+
|
|
|
+module_init(apm_battery_init);
|
|
|
+module_exit(apm_battery_exit);
|
|
|
+
|
|
|
+MODULE_AUTHOR("Eugeny Boger <eugenyboger@dgap.mipt.ru>");
|
|
|
+MODULE_DESCRIPTION("APM emulation driver for battery monitoring class");
|
|
|
+MODULE_LICENSE("GPL");
|