Browse Source

bnx2x: prevent timeouts when using PFC

Prevent updating the xmac PFC configuration when using a link speed
slower than 10G -the umac block is responsible for 1G or slower connections,
therefore it is possible the xmac block is reset when connection is slower.

Signed-off-by: Yaniv Rosner <yaniv.rosner@broadcom.com>
Signed-off-by: Yuval Mintz <yuvalmin@broadcom.com>
Signed-off-by: Eilon Greenstein <eilong@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Yaniv Rosner 12 years ago
parent
commit
375944cb7c
1 changed files with 5 additions and 3 deletions
  1. 5 3
      drivers/net/ethernet/broadcom/bnx2x/bnx2x_link.c

+ 5 - 3
drivers/net/ethernet/broadcom/bnx2x/bnx2x_link.c

@@ -2667,9 +2667,11 @@ int bnx2x_update_pfc(struct link_params *params,
 		return bnx2x_status;
 
 	DP(NETIF_MSG_LINK, "About to update PFC in BMAC\n");
-	if (CHIP_IS_E3(bp))
-		bnx2x_update_pfc_xmac(params, vars, 0);
-	else {
+
+	if (CHIP_IS_E3(bp)) {
+		if (vars->mac_type == MAC_TYPE_XMAC)
+			bnx2x_update_pfc_xmac(params, vars, 0);
+	} else {
 		val = REG_RD(bp, MISC_REG_RESET_REG_2);
 		if ((val &
 		     (MISC_REGISTERS_RESET_REG_2_RST_BMAC0 << params->port))