Browse Source

spi-topcliff-pch: Fix CPU read complete condition issue

We found Rx data sometimes drops.(with non-DMA transfer mode)
The cause is read complete condition is not true.

This patch fixes the issue.

Signed-off-by: Tomoya MORINAGA <tomoya-linux@dsn.okisemi.com>
Signed-off-by: Grant Likely <grant.likely@secretlab.ca>
Tomoya MORINAGA 13 years ago
parent
commit
373b0eb64b
1 changed files with 11 additions and 8 deletions
  1. 11 8
      drivers/spi/spi-topcliff-pch.c

+ 11 - 8
drivers/spi/spi-topcliff-pch.c

@@ -317,16 +317,19 @@ static void pch_spi_handler_sub(struct pch_spi_data *data, u32 reg_spsr_val,
 
 	/* if transfer complete interrupt */
 	if (reg_spsr_val & SPSR_FI_BIT) {
-		if (tx_index < bpw_len)
+		if ((tx_index == bpw_len) && (rx_index == tx_index)) {
+			/* disable interrupts */
+			pch_spi_setclr_reg(data->master, PCH_SPCR, 0, PCH_ALL);
+
+			/* transfer is completed;
+			   inform pch_spi_process_messages */
+			data->transfer_complete = true;
+			data->transfer_active = false;
+			wake_up(&data->wait);
+		} else {
 			dev_err(&data->master->dev,
 				"%s : Transfer is not completed", __func__);
-		/* disable interrupts */
-		pch_spi_setclr_reg(data->master, PCH_SPCR, 0, PCH_ALL);
-
-		/* transfer is completed;inform pch_spi_process_messages */
-		data->transfer_complete = true;
-		data->transfer_active = false;
-		wake_up(&data->wait);
+		}
 	}
 }