Prechádzať zdrojové kódy

powerpc/pci: fix PCI-e check link issue

For Freescale powerpc platform, the PCI-e bus number uses the reassign mode
by default. It means the second PCI-e controller's hose->first_busno is the
first controller's last bus number adding 1. For some hotpluged device(or
controlled by FPGA), the device is linked to PCI-e slot at linux runtime.
It needs rescan for the system to add it and driver it to work. It successes
to rescan the device linked to the first PCI-e controller's slot, but fails to
rescan the device linked to the second PCI-e controller's slot. The cause is
that the bus->number is reset to 0, which isn't equal to the hose->first_busno
for the second controller checking PCI-e link. So it doesn't really check the
PCI-e link status, the link status is always no_link. The device won't be
really rescaned. Reset the bus->number to hose->first_busno in the function
fsl_pcie_check_link(), it will do the real checking PCI-e link status for the
second controller, the device will be rescaned.

Signed-off-by: Yuanquan Chen <Yuanquan.Chen@freescale.com>
Tested-by: Rojhalat Ibrahim <imr@rtschenk.de>
Signed-off-by: Scott Wood <scottwood@freescale.com>
Yuanquan Chen 12 rokov pred
rodič
commit
36f6849400
1 zmenil súbory, kde vykonal 1 pridanie a 1 odobranie
  1. 1 1
      arch/powerpc/sysdev/fsl_pci.c

+ 1 - 1
arch/powerpc/sysdev/fsl_pci.c

@@ -68,7 +68,7 @@ static int fsl_pcie_check_link(struct pci_controller *hose)
 	if (hose->indirect_type & PPC_INDIRECT_TYPE_FSL_CFG_REG_LINK) {
 		if (hose->ops->read == fsl_indirect_read_config) {
 			struct pci_bus bus;
-			bus.number = 0;
+			bus.number = hose->first_busno;
 			bus.sysdata = hose;
 			bus.ops = hose->ops;
 			indirect_read_config(&bus, 0, PCIE_LTSSM, 4, &val);