@@ -16,6 +16,21 @@ Optional properties:
|
|
|
- interrupts: Interrupt specifiers for interrupt sources.
|
|
|
|
|
|
Optional nodes:
|
|
|
+- clocks: s2mps11 provides three(AP/CP/BT) buffered 32.768 KHz outputs, so to
|
|
|
+ register these as clocks with common clock framework instantiate a sub-node
|
|
|
+ named "clocks". It uses the common clock binding documented in :
|
|
|
+ [Documentation/devicetree/bindings/clock/clock-bindings.txt]
|
|
|
+ - #clock-cells: should be 1.
|
|
|
+
|
|
|
+ - The following is the list of clocks generated by the controller. Each clock
|
|
|
+ is assigned an identifier and client nodes use this identifier to specify
|
|
|
+ the clock which they consume.
|
|
|
+ Clock ID
|
|
|
+ ----------------------
|
|
|
+ 32KhzAP 0
|
|
|
+ 32KhzCP 1
|
|
|
+ 32KhzBT 2
|
|
|
+
|
|
|
- regulators: The regulators of s2mps11 that have to be instantiated should be
|
|
|
included in a sub-node named 'regulators'. Regulator nodes included in this
|
|
|
sub-node should be of the format as listed below.
|
|
@@ -55,6 +70,11 @@ Example:
|
|
|
compatible = "samsung,s2mps11-pmic";
|
|
|
reg = <0x66>;
|
|
|
|
|
|
+ s2m_osc: clocks{
|
|
|
+ #clock-cells = 1;
|
|
|
+ clock-output-names = "xx", "yy", "zz";
|
|
|
+ };
|
|
|
+
|
|
|
regulators {
|
|
|
ldo1_reg: LDO1 {
|
|
|
regulator-name = "VDD_ABB_3.3V";
|