drivers/rtc/rtc-pl031.c: enable clock on all ST variants

The ST variants of the PL031 all require bit 26 in the control register
to be set before they work properly.  Discovered this when testing on
the Nomadik board where it would suprisingly just stand still.

Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Cc: Mian Yousaf Kaukab <mian.yousaf.kaukab@stericsson.com>
Cc: Alessandro Rubini <rubini@unipv.it>
Cc: <stable@vger.kernel.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Linus Walleij 13 жил өмнө
parent
commit
2f39721683

+ 1 - 2
drivers/rtc/rtc-pl031.c

@@ -339,8 +339,7 @@ static int pl031_probe(struct amba_device *adev, const struct amba_id *id)
 	dev_dbg(&adev->dev, "revision = 0x%01x\n", ldata->hw_revision);
 
 	/* Enable the clockwatch on ST Variants */
-	if ((ldata->hw_designer == AMBA_VENDOR_ST) &&
-	    (ldata->hw_revision > 1))
+	if (ldata->hw_designer == AMBA_VENDOR_ST)
 		writel(readl(ldata->base + RTC_CR) | RTC_CR_CWEN,
 		       ldata->base + RTC_CR);