@@ -1064,6 +1064,13 @@ s32 ixgbe_setup_fc(struct ixgbe_hw *hw, s32 packetbuf_num)
|
|
|
rmcs_reg = IXGBE_READ_REG(hw, IXGBE_RMCS);
|
|
|
rmcs_reg &= ~(IXGBE_RMCS_TFCE_PRIORITY | IXGBE_RMCS_TFCE_802_3X);
|
|
|
|
|
|
+ /*
|
|
|
+ * 10 gig parts do not have a word in the EEPROM to determine the
|
|
|
+ * default flow control setting, so we explicitly set it to full.
|
|
|
+ */
|
|
|
+ if (hw->fc.type == ixgbe_fc_default)
|
|
|
+ hw->fc.type = ixgbe_fc_full;
|
|
|
+
|
|
|
/*
|
|
|
* We want to save off the original Flow Control configuration just in
|
|
|
* case we get disconnected and then reconnected into a different hub
|
|
@@ -1116,6 +1123,16 @@ s32 ixgbe_setup_fc(struct ixgbe_hw *hw, s32 packetbuf_num)
|
|
|
IXGBE_WRITE_REG(hw, IXGBE_FCTRL, frctl_reg);
|
|
|
IXGBE_WRITE_REG(hw, IXGBE_RMCS, rmcs_reg);
|
|
|
|
|
|
+ /*
|
|
|
+ * Check for invalid software configuration, zeros are completely
|
|
|
+ * invalid for all parameters used past this point, and if we enable
|
|
|
+ * flow control with zero water marks, we blast flow control packets.
|
|
|
+ */
|
|
|
+ if (!hw->fc.low_water || !hw->fc.high_water || !hw->fc.pause_time) {
|
|
|
+ hw_dbg(hw, "Flow control structure initialized incorrectly\n");
|
|
|
+ return IXGBE_ERR_INVALID_LINK_SETTINGS;
|
|
|
+ }
|
|
|
+
|
|
|
/*
|
|
|
* We need to set up the Receive Threshold high and low water
|
|
|
* marks as well as (optionally) enabling the transmission of
|