@@ -758,35 +758,119 @@ u16 bnx2x_get_mf_speed(struct bnx2x *bp)
|
|
|
return line_speed;
|
|
|
}
|
|
|
|
|
|
+/**
|
|
|
+ * bnx2x_fill_report_data - fill link report data to report
|
|
|
+ *
|
|
|
+ * @bp: driver handle
|
|
|
+ * @data: link state to update
|
|
|
+ *
|
|
|
+ * It uses a none-atomic bit operations because is called under the mutex.
|
|
|
+ */
|
|
|
+static inline void bnx2x_fill_report_data(struct bnx2x *bp,
|
|
|
+ struct bnx2x_link_report_data *data)
|
|
|
+{
|
|
|
+ u16 line_speed = bnx2x_get_mf_speed(bp);
|
|
|
+
|
|
|
+ memset(data, 0, sizeof(*data));
|
|
|
+
|
|
|
+ /* Fill the report data: efective line speed */
|
|
|
+ data->line_speed = line_speed;
|
|
|
+
|
|
|
+ /* Link is down */
|
|
|
+ if (!bp->link_vars.link_up || (bp->flags & MF_FUNC_DIS))
|
|
|
+ __set_bit(BNX2X_LINK_REPORT_LINK_DOWN,
|
|
|
+ &data->link_report_flags);
|
|
|
+
|
|
|
+ /* Full DUPLEX */
|
|
|
+ if (bp->link_vars.duplex == DUPLEX_FULL)
|
|
|
+ __set_bit(BNX2X_LINK_REPORT_FD, &data->link_report_flags);
|
|
|
+
|
|
|
+ /* Rx Flow Control is ON */
|
|
|
+ if (bp->link_vars.flow_ctrl & BNX2X_FLOW_CTRL_RX)
|
|
|
+ __set_bit(BNX2X_LINK_REPORT_RX_FC_ON, &data->link_report_flags);
|
|
|
+
|
|
|
+ /* Tx Flow Control is ON */
|
|
|
+ if (bp->link_vars.flow_ctrl & BNX2X_FLOW_CTRL_TX)
|
|
|
+ __set_bit(BNX2X_LINK_REPORT_TX_FC_ON, &data->link_report_flags);
|
|
|
+}
|
|
|
+
|
|
|
+/**
|
|
|
+ * bnx2x_link_report - report link status to OS.
|
|
|
+ *
|
|
|
+ * @bp: driver handle
|
|
|
+ *
|
|
|
+ * Calls the __bnx2x_link_report() under the same locking scheme
|
|
|
+ * as a link/PHY state managing code to ensure a consistent link
|
|
|
+ * reporting.
|
|
|
+ */
|
|
|
+
|
|
|
void bnx2x_link_report(struct bnx2x *bp)
|
|
|
{
|
|
|
- if (bp->flags & MF_FUNC_DIS) {
|
|
|
- netif_carrier_off(bp->dev);
|
|
|
- netdev_err(bp->dev, "NIC Link is Down\n");
|
|
|
- return;
|
|
|
- }
|
|
|
+ bnx2x_acquire_phy_lock(bp);
|
|
|
+ __bnx2x_link_report(bp);
|
|
|
+ bnx2x_release_phy_lock(bp);
|
|
|
+}
|
|
|
|
|
|
- if (bp->link_vars.link_up) {
|
|
|
- u16 line_speed;
|
|
|
+/**
|
|
|
+ * __bnx2x_link_report - report link status to OS.
|
|
|
+ *
|
|
|
+ * @bp: driver handle
|
|
|
+ *
|
|
|
+ * None atomic inmlementation.
|
|
|
+ * Should be called under the phy_lock.
|
|
|
+ */
|
|
|
+void __bnx2x_link_report(struct bnx2x *bp)
|
|
|
+{
|
|
|
+ struct bnx2x_link_report_data cur_data;
|
|
|
|
|
|
- if (bp->state == BNX2X_STATE_OPEN)
|
|
|
- netif_carrier_on(bp->dev);
|
|
|
- netdev_info(bp->dev, "NIC Link is Up, ");
|
|
|
+ /* reread mf_cfg */
|
|
|
+ if (!CHIP_IS_E1(bp))
|
|
|
+ bnx2x_read_mf_cfg(bp);
|
|
|
+
|
|
|
+ /* Read the current link report info */
|
|
|
+ bnx2x_fill_report_data(bp, &cur_data);
|
|
|
+
|
|
|
+ /* Don't report link down or exactly the same link status twice */
|
|
|
+ if (!memcmp(&cur_data, &bp->last_reported_link, sizeof(cur_data)) ||
|
|
|
+ (test_bit(BNX2X_LINK_REPORT_LINK_DOWN,
|
|
|
+ &bp->last_reported_link.link_report_flags) &&
|
|
|
+ test_bit(BNX2X_LINK_REPORT_LINK_DOWN,
|
|
|
+ &cur_data.link_report_flags)))
|
|
|
+ return;
|
|
|
+
|
|
|
+ bp->link_cnt++;
|
|
|
|
|
|
- line_speed = bnx2x_get_mf_speed(bp);
|
|
|
+ /* We are going to report a new link parameters now -
|
|
|
+ * remember the current data for the next time.
|
|
|
+ */
|
|
|
+ memcpy(&bp->last_reported_link, &cur_data, sizeof(cur_data));
|
|
|
|
|
|
- pr_cont("%d Mbps ", line_speed);
|
|
|
+ if (test_bit(BNX2X_LINK_REPORT_LINK_DOWN,
|
|
|
+ &cur_data.link_report_flags)) {
|
|
|
+ netif_carrier_off(bp->dev);
|
|
|
+ netdev_err(bp->dev, "NIC Link is Down\n");
|
|
|
+ return;
|
|
|
+ } else {
|
|
|
+ netif_carrier_on(bp->dev);
|
|
|
+ netdev_info(bp->dev, "NIC Link is Up, ");
|
|
|
+ pr_cont("%d Mbps ", cur_data.line_speed);
|
|
|
|
|
|
- if (bp->link_vars.duplex == DUPLEX_FULL)
|
|
|
+ if (test_and_clear_bit(BNX2X_LINK_REPORT_FD,
|
|
|
+ &cur_data.link_report_flags))
|
|
|
pr_cont("full duplex");
|
|
|
else
|
|
|
pr_cont("half duplex");
|
|
|
|
|
|
- if (bp->link_vars.flow_ctrl != BNX2X_FLOW_CTRL_NONE) {
|
|
|
- if (bp->link_vars.flow_ctrl & BNX2X_FLOW_CTRL_RX) {
|
|
|
+ /* Handle the FC at the end so that only these flags would be
|
|
|
+ * possibly set. This way we may easily check if there is no FC
|
|
|
+ * enabled.
|
|
|
+ */
|
|
|
+ if (cur_data.link_report_flags) {
|
|
|
+ if (test_bit(BNX2X_LINK_REPORT_RX_FC_ON,
|
|
|
+ &cur_data.link_report_flags)) {
|
|
|
pr_cont(", receive ");
|
|
|
- if (bp->link_vars.flow_ctrl &
|
|
|
- BNX2X_FLOW_CTRL_TX)
|
|
|
+ if (test_bit(BNX2X_LINK_REPORT_TX_FC_ON,
|
|
|
+ &cur_data.link_report_flags))
|
|
|
pr_cont("& transmit ");
|
|
|
} else {
|
|
|
pr_cont(", transmit ");
|
|
@@ -794,10 +878,6 @@ void bnx2x_link_report(struct bnx2x *bp)
|
|
|
pr_cont("flow control ON");
|
|
|
}
|
|
|
pr_cont("\n");
|
|
|
-
|
|
|
- } else { /* link_down */
|
|
|
- netif_carrier_off(bp->dev);
|
|
|
- netdev_err(bp->dev, "NIC Link is Down\n");
|
|
|
}
|
|
|
}
|
|
|
|
|
@@ -1345,6 +1425,13 @@ int bnx2x_nic_load(struct bnx2x *bp, int load_mode)
|
|
|
|
|
|
bp->state = BNX2X_STATE_OPENING_WAIT4_LOAD;
|
|
|
|
|
|
+ /* Set the initial link reported state to link down */
|
|
|
+ bnx2x_acquire_phy_lock(bp);
|
|
|
+ memset(&bp->last_reported_link, 0, sizeof(bp->last_reported_link));
|
|
|
+ __set_bit(BNX2X_LINK_REPORT_LINK_DOWN,
|
|
|
+ &bp->last_reported_link.link_report_flags);
|
|
|
+ bnx2x_release_phy_lock(bp);
|
|
|
+
|
|
|
/* must be called before memory allocation and HW init */
|
|
|
bnx2x_ilt_set_info(bp);
|
|
|
|