@@ -49,12 +49,9 @@ of up to +/- 0.5 degrees even when compared against precise temperature
|
|
|
readings. Be sure to have a high vs. low temperature limit gap of al least
|
|
|
1.0 degree Celsius to avoid Tout "bouncing", though!
|
|
|
|
|
|
-As for alarms, you can read the alarm status of the DS1621 via the 'alarms'
|
|
|
-/sys file interface. The result consists mainly of bit 6 and 5 of the
|
|
|
-configuration register of the chip; bit 6 (0x40 or 64) is the high alarm
|
|
|
-bit and bit 5 (0x20 or 32) the low one. These bits are set when the high or
|
|
|
-low limits are met or exceeded and are reset by the module as soon as the
|
|
|
-respective temperature ranges are left.
|
|
|
+The alarm bits are set when the high or low limits are met or exceeded and
|
|
|
+are reset by the module as soon as the respective temperature ranges are
|
|
|
+left.
|
|
|
|
|
|
The alarm registers are in no way suitable to find out about the actual
|
|
|
status of Tout. They will only tell you about its history, whether or not
|
|
@@ -64,45 +61,3 @@ with neither of the alarms set.
|
|
|
|
|
|
Temperature conversion of the DS1621 takes up to 1000ms; internal access to
|
|
|
non-volatile registers may last for 10ms or below.
|
|
|
-
|
|
|
-High Accuracy Temperature Reading
|
|
|
----------------------------------
|
|
|
-
|
|
|
-As said before, the temperature issued via the 9-bit i2c-bus data is
|
|
|
-somewhat arbitrary. Internally, the temperature conversion is of a
|
|
|
-different kind that is explained (not so...) well in the DS1621 data sheet.
|
|
|
-To cut the long story short: Inside the DS1621 there are two oscillators,
|
|
|
-both of them biassed by a temperature coefficient.
|
|
|
-
|
|
|
-Higher resolution of the temperature reading can be achieved using the
|
|
|
-internal projection, which means taking account of REG_COUNT and REG_SLOPE
|
|
|
-(the driver manages them):
|
|
|
-
|
|
|
-Taken from Dallas Semiconductors App Note 068: 'Increasing Temperature
|
|
|
-Resolution on the DS1620' and App Note 105: 'High Resolution Temperature
|
|
|
-Measurement with Dallas Direct-to-Digital Temperature Sensors'
|
|
|
-
|
|
|
-- Read the 9-bit temperature and strip the LSB (Truncate the .5 degs)
|
|
|
-- The resulting value is TEMP_READ.
|
|
|
-- Then, read REG_COUNT.
|
|
|
-- And then, REG_SLOPE.
|
|
|
-
|
|
|
- TEMP = TEMP_READ - 0.25 + ((REG_SLOPE - REG_COUNT) / REG_SLOPE)
|
|
|
-
|
|
|
-Note that this is what the DONE bit in the DS1621 configuration register is
|
|
|
-good for: Internally, one temperature conversion takes up to 1000ms. Before
|
|
|
-that conversion is complete you will not be able to read valid things out
|
|
|
-of REG_COUNT and REG_SLOPE. The DONE bit, as you may have guessed by now,
|
|
|
-tells you whether the conversion is complete ("done", in plain English) and
|
|
|
-thus, whether the values you read are good or not.
|
|
|
-
|
|
|
-The DS1621 has two modes of operation: "Continuous" conversion, which can
|
|
|
-be understood as the default stand-alone mode where the chip gets the
|
|
|
-temperature and controls external devices via its Tout pin or tells other
|
|
|
-i2c's about it if they care. The other mode is called "1SHOT", that means
|
|
|
-that it only figures out about the temperature when it is explicitly told
|
|
|
-to do so; this can be seen as power saving mode.
|
|
|
-
|
|
|
-Now if you want to read REG_COUNT and REG_SLOPE, you have to either stop
|
|
|
-the continuous conversions until the contents of these registers are valid,
|
|
|
-or, in 1SHOT mode, you have to have one conversion made.
|