|
@@ -86,6 +86,11 @@ MODULE_PARM_DESC(exclusive_login, "Exclusive login to sbp2 device "
|
|
|
* - delay inquiry
|
|
|
* Wait extra SBP2_INQUIRY_DELAY seconds after login before SCSI inquiry.
|
|
|
*
|
|
|
+ * - power condition
|
|
|
+ * Set the power condition field in the START STOP UNIT commands sent by
|
|
|
+ * sd_mod on suspend, resume, and shutdown (if manage_start_stop is on).
|
|
|
+ * Some disks need this to spin down or to resume properly.
|
|
|
+ *
|
|
|
* - override internal blacklist
|
|
|
* Instead of adding to the built-in blacklist, use only the workarounds
|
|
|
* specified in the module load parameter.
|
|
@@ -97,6 +102,7 @@ MODULE_PARM_DESC(exclusive_login, "Exclusive login to sbp2 device "
|
|
|
#define SBP2_WORKAROUND_FIX_CAPACITY 0x8
|
|
|
#define SBP2_WORKAROUND_DELAY_INQUIRY 0x10
|
|
|
#define SBP2_INQUIRY_DELAY 12
|
|
|
+#define SBP2_WORKAROUND_POWER_CONDITION 0x20
|
|
|
#define SBP2_WORKAROUND_OVERRIDE 0x100
|
|
|
|
|
|
static int sbp2_param_workarounds;
|
|
@@ -107,6 +113,8 @@ MODULE_PARM_DESC(workarounds, "Work around device bugs (default = 0"
|
|
|
", skip mode page 8 = " __stringify(SBP2_WORKAROUND_MODE_SENSE_8)
|
|
|
", fix capacity = " __stringify(SBP2_WORKAROUND_FIX_CAPACITY)
|
|
|
", delay inquiry = " __stringify(SBP2_WORKAROUND_DELAY_INQUIRY)
|
|
|
+ ", set power condition in start stop unit = "
|
|
|
+ __stringify(SBP2_WORKAROUND_POWER_CONDITION)
|
|
|
", override internal blacklist = " __stringify(SBP2_WORKAROUND_OVERRIDE)
|
|
|
", or a combination)");
|
|
|
|
|
@@ -310,18 +318,25 @@ static const struct {
|
|
|
.firmware_revision = 0x002800,
|
|
|
.model = 0x001010,
|
|
|
.workarounds = SBP2_WORKAROUND_INQUIRY_36 |
|
|
|
- SBP2_WORKAROUND_MODE_SENSE_8,
|
|
|
+ SBP2_WORKAROUND_MODE_SENSE_8 |
|
|
|
+ SBP2_WORKAROUND_POWER_CONDITION,
|
|
|
},
|
|
|
/* DViCO Momobay FX-3A with TSB42AA9A bridge */ {
|
|
|
.firmware_revision = 0x002800,
|
|
|
.model = 0x000000,
|
|
|
- .workarounds = SBP2_WORKAROUND_DELAY_INQUIRY,
|
|
|
+ .workarounds = SBP2_WORKAROUND_DELAY_INQUIRY |
|
|
|
+ SBP2_WORKAROUND_POWER_CONDITION,
|
|
|
},
|
|
|
/* Initio bridges, actually only needed for some older ones */ {
|
|
|
.firmware_revision = 0x000200,
|
|
|
.model = ~0,
|
|
|
.workarounds = SBP2_WORKAROUND_INQUIRY_36,
|
|
|
},
|
|
|
+ /* PL-3507 bridge with Prolific firmware */ {
|
|
|
+ .firmware_revision = 0x012800,
|
|
|
+ .model = ~0,
|
|
|
+ .workarounds = SBP2_WORKAROUND_POWER_CONDITION,
|
|
|
+ },
|
|
|
/* Symbios bridge */ {
|
|
|
.firmware_revision = 0xa0b800,
|
|
|
.model = ~0,
|
|
@@ -1530,6 +1545,9 @@ static int sbp2_scsi_slave_configure(struct scsi_device *sdev)
|
|
|
|
|
|
sdev->use_10_for_rw = 1;
|
|
|
|
|
|
+ if (sbp2_param_exclusive_login)
|
|
|
+ sdev->manage_start_stop = 1;
|
|
|
+
|
|
|
if (sdev->type == TYPE_ROM)
|
|
|
sdev->use_10_for_ms = 1;
|
|
|
|
|
@@ -1540,6 +1558,9 @@ static int sbp2_scsi_slave_configure(struct scsi_device *sdev)
|
|
|
if (lu->tgt->workarounds & SBP2_WORKAROUND_FIX_CAPACITY)
|
|
|
sdev->fix_capacity = 1;
|
|
|
|
|
|
+ if (lu->tgt->workarounds & SBP2_WORKAROUND_POWER_CONDITION)
|
|
|
+ sdev->start_stop_pwr_cond = 1;
|
|
|
+
|
|
|
if (lu->tgt->workarounds & SBP2_WORKAROUND_128K_MAX_TRANS)
|
|
|
blk_queue_max_sectors(sdev->request_queue, 128 * 1024 / 512);
|
|
|
|