Browse Source

ARM: S5PV210: use dma-pl330 device name for clock

This change replaces s3c-pl330.x clock device names with dma-pl330.x,
otherwise there won't be a correspondence between clock device name
and amba device name, thus clocks can't be enabled.

Fixes runtime errors on clk_get() from drivers/dma/pl330.c:
  dma-pl330 dma-pl330.0: Cannot get operation clock.
  dma-pl330: probe of dma-pl330.0 failed with error -22

Signed-off-by: Vladimir Zapolskiy <vz@mleia.com>
Acked-by: Boojin Kim <boojin.kim@samsung.com>
Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
Vladimir Zapolskiy 14 years ago
parent
commit
1ce3ea61c6
1 changed files with 2 additions and 2 deletions
  1. 2 2
      arch/arm/mach-s5pv210/clock.c

+ 2 - 2
arch/arm/mach-s5pv210/clock.c

@@ -290,13 +290,13 @@ static struct clk_ops clk_fout_apll_ops = {
 static struct clk init_clocks_off[] = {
 	{
 		.name		= "pdma",
-		.devname	= "s3c-pl330.0",
+		.devname	= "dma-pl330.0",
 		.parent		= &clk_hclk_psys.clk,
 		.enable		= s5pv210_clk_ip0_ctrl,
 		.ctrlbit	= (1 << 3),
 	}, {
 		.name		= "pdma",
-		.devname	= "s3c-pl330.1",
+		.devname	= "dma-pl330.1",
 		.parent		= &clk_hclk_psys.clk,
 		.enable		= s5pv210_clk_ip0_ctrl,
 		.ctrlbit	= (1 << 4),