@@ -175,11 +175,13 @@ currX_crit Critical maximum current.
|
|
|
From IIN_OC_FAULT_LIMIT or IOUT_OC_FAULT_LIMIT register.
|
|
|
currX_alarm Current high alarm.
|
|
|
From IIN_OC_WARNING or IOUT_OC_WARNING status.
|
|
|
+currX_max_alarm Current high alarm.
|
|
|
+ From IIN_OC_WARN_LIMIT or IOUT_OC_WARN_LIMIT status.
|
|
|
currX_lcrit_alarm Output current critical low alarm.
|
|
|
From IOUT_UC_FAULT status.
|
|
|
currX_crit_alarm Current critical high alarm.
|
|
|
From IIN_OC_FAULT or IOUT_OC_FAULT status.
|
|
|
-currX_label "iin" or "vinY"
|
|
|
+currX_label "iin" or "ioutY"
|
|
|
|
|
|
powerX_input Measured power. From READ_PIN or READ_POUT register.
|
|
|
powerX_cap Output power cap. From POUT_MAX register.
|
|
@@ -193,13 +195,13 @@ powerX_crit_alarm Output power critical high alarm.
|
|
|
From POUT_OP_FAULT status.
|
|
|
powerX_label "pin" or "poutY"
|
|
|
|
|
|
-tempX_input Measured tempererature.
|
|
|
+tempX_input Measured temperature.
|
|
|
From READ_TEMPERATURE_X register.
|
|
|
-tempX_min Mimimum tempererature. From UT_WARN_LIMIT register.
|
|
|
-tempX_max Maximum tempererature. From OT_WARN_LIMIT register.
|
|
|
-tempX_lcrit Critical low tempererature.
|
|
|
+tempX_min Mimimum temperature. From UT_WARN_LIMIT register.
|
|
|
+tempX_max Maximum temperature. From OT_WARN_LIMIT register.
|
|
|
+tempX_lcrit Critical low temperature.
|
|
|
From UT_FAULT_LIMIT register.
|
|
|
-tempX_crit Critical high tempererature.
|
|
|
+tempX_crit Critical high temperature.
|
|
|
From OT_FAULT_LIMIT register.
|
|
|
tempX_min_alarm Chip temperature low alarm. Set by comparing
|
|
|
READ_TEMPERATURE_X with UT_WARN_LIMIT if
|