Browse Source

bnx2x: Handling PHY FW load failure

If the default PHY version (0x4321) is read - the PHY FW load failed

Signed-off-by: Yaniv Rosner <yanivr@broadcom.com>
Signed-off-by: Eilon Greenstein <eilong@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Eilon Greenstein 16 years ago
parent
commit
16b311cc29
1 changed files with 4 additions and 3 deletions
  1. 4 3
      drivers/net/bnx2x_link.c

+ 4 - 3
drivers/net/bnx2x_link.c

@@ -4404,10 +4404,11 @@ static u8 bnx2x_8073_common_init_phy(struct bnx2x *bp, u32 shmem_base)
 			      ext_phy_addr[port],
 			      MDIO_PMA_DEVAD,
 			      MDIO_PMA_REG_ROM_VER1, &fw_ver1);
-		if (fw_ver1 == 0) {
+		if (fw_ver1 == 0 || fw_ver1 == 0x4321) {
 			DP(NETIF_MSG_LINK,
-				 "bnx2x_8073_common_init_phy port %x "
-				 "fw Download failed\n", port);
+				 "bnx2x_8073_common_init_phy port %x:"
+				 "Download failed. fw version = 0x%x\n",
+				 port, fw_ver1);
 			return -EINVAL;
 		}