@@ -83,6 +83,7 @@ static int ibm_read_slot_reset_state;
|
|
|
static int ibm_read_slot_reset_state2;
|
|
|
static int ibm_slot_error_detail;
|
|
|
static int ibm_get_config_addr_info;
|
|
|
+static int ibm_get_config_addr_info2;
|
|
|
static int ibm_configure_bridge;
|
|
|
|
|
|
int eeh_subsystem_enabled;
|
|
@@ -744,6 +745,38 @@ struct eeh_early_enable_info {
|
|
|
unsigned int buid_lo;
|
|
|
};
|
|
|
|
|
|
+static int get_pe_addr (int config_addr,
|
|
|
+ struct eeh_early_enable_info *info)
|
|
|
+{
|
|
|
+ unsigned int rets[3];
|
|
|
+ int ret;
|
|
|
+
|
|
|
+ /* Use latest config-addr token on power6 */
|
|
|
+ if (ibm_get_config_addr_info2 != RTAS_UNKNOWN_SERVICE) {
|
|
|
+ /* Make sure we have a PE in hand */
|
|
|
+ ret = rtas_call (ibm_get_config_addr_info2, 4, 2, rets,
|
|
|
+ config_addr, info->buid_hi, info->buid_lo, 1);
|
|
|
+ if (ret || (rets[0]==0))
|
|
|
+ return 0;
|
|
|
+
|
|
|
+ ret = rtas_call (ibm_get_config_addr_info2, 4, 2, rets,
|
|
|
+ config_addr, info->buid_hi, info->buid_lo, 0);
|
|
|
+ if (ret)
|
|
|
+ return 0;
|
|
|
+ return rets[0];
|
|
|
+ }
|
|
|
+
|
|
|
+ /* Use older config-addr token on power5 */
|
|
|
+ if (ibm_get_config_addr_info != RTAS_UNKNOWN_SERVICE) {
|
|
|
+ ret = rtas_call (ibm_get_config_addr_info, 4, 2, rets,
|
|
|
+ config_addr, info->buid_hi, info->buid_lo, 0);
|
|
|
+ if (ret)
|
|
|
+ return 0;
|
|
|
+ return rets[0];
|
|
|
+ }
|
|
|
+ return 0;
|
|
|
+}
|
|
|
+
|
|
|
/* Enable eeh for the given device node. */
|
|
|
static void *early_enable_eeh(struct device_node *dn, void *data)
|
|
|
{
|
|
@@ -810,15 +843,7 @@ static void *early_enable_eeh(struct device_node *dn, void *data)
|
|
|
|
|
|
/* If the newer, better, ibm,get-config-addr-info is supported,
|
|
|
* then use that instead. */
|
|
|
- pdn->eeh_pe_config_addr = 0;
|
|
|
- if (ibm_get_config_addr_info != RTAS_UNKNOWN_SERVICE) {
|
|
|
- ret = rtas_call (ibm_get_config_addr_info, 4, 2, rets,
|
|
|
- pdn->eeh_config_addr,
|
|
|
- info->buid_hi, info->buid_lo,
|
|
|
- 0);
|
|
|
- if (ret == 0)
|
|
|
- pdn->eeh_pe_config_addr = rets[0];
|
|
|
- }
|
|
|
+ pdn->eeh_pe_config_addr = get_pe_addr(pdn->eeh_config_addr, info);
|
|
|
|
|
|
/* Some older systems (Power4) allow the
|
|
|
* ibm,set-eeh-option call to succeed even on nodes
|
|
@@ -889,6 +914,7 @@ void __init eeh_init(void)
|
|
|
ibm_read_slot_reset_state = rtas_token("ibm,read-slot-reset-state");
|
|
|
ibm_slot_error_detail = rtas_token("ibm,slot-error-detail");
|
|
|
ibm_get_config_addr_info = rtas_token("ibm,get-config-addr-info");
|
|
|
+ ibm_get_config_addr_info2 = rtas_token("ibm,get-config-addr-info2");
|
|
|
ibm_configure_bridge = rtas_token ("ibm,configure-bridge");
|
|
|
|
|
|
if (ibm_set_eeh_option == RTAS_UNKNOWN_SERVICE)
|