@@ -1262,30 +1262,6 @@ static enum sci_status default_port_handler(struct scic_sds_port *sci_port,
|
|
|
return SCI_FAILURE_INVALID_STATE;
|
|
|
}
|
|
|
|
|
|
-/*
|
|
|
- * This is the default method for a port unsolicited frame request. It will
|
|
|
- * report a warning and exit. enum sci_status SCI_FAILURE_INVALID_STATE Is it even
|
|
|
- * possible to receive an unsolicited frame directed to a port object? It
|
|
|
- * seems possible if we implementing virtual functions but until then?
|
|
|
- */
|
|
|
-static enum sci_status
|
|
|
-scic_sds_port_default_frame_handler(struct scic_sds_port *sci_port,
|
|
|
- u32 frame_index)
|
|
|
-{
|
|
|
- struct scic_sds_controller *scic = scic_sds_port_get_controller(sci_port);
|
|
|
-
|
|
|
- default_port_handler(sci_port, __func__);
|
|
|
- scic_sds_controller_release_frame(scic, frame_index);
|
|
|
-
|
|
|
- return SCI_FAILURE_INVALID_STATE;
|
|
|
-}
|
|
|
-
|
|
|
-static enum sci_status scic_sds_port_default_event_handler(struct scic_sds_port *sci_port,
|
|
|
- u32 event_code)
|
|
|
-{
|
|
|
- return default_port_handler(sci_port, __func__);
|
|
|
-}
|
|
|
-
|
|
|
static void scic_sds_port_default_link_up_handler(struct scic_sds_port *sci_port,
|
|
|
struct scic_sds_phy *sci_phy)
|
|
|
{
|
|
@@ -1925,64 +1901,48 @@ enum sci_status scic_sds_port_remove_phy(struct scic_sds_port *sci_port,
|
|
|
|
|
|
static struct scic_sds_port_state_handler scic_sds_port_state_handler_table[] = {
|
|
|
[SCI_BASE_PORT_STATE_STOPPED] = {
|
|
|
- .frame_handler = scic_sds_port_default_frame_handler,
|
|
|
- .event_handler = scic_sds_port_default_event_handler,
|
|
|
.link_up_handler = scic_sds_port_default_link_up_handler,
|
|
|
.link_down_handler = scic_sds_port_default_link_down_handler,
|
|
|
.start_io_handler = scic_sds_port_default_start_io_handler,
|
|
|
.complete_io_handler = scic_sds_port_default_complete_io_handler
|
|
|
},
|
|
|
[SCI_BASE_PORT_STATE_STOPPING] = {
|
|
|
- .frame_handler = scic_sds_port_default_frame_handler,
|
|
|
- .event_handler = scic_sds_port_default_event_handler,
|
|
|
.link_up_handler = scic_sds_port_default_link_up_handler,
|
|
|
.link_down_handler = scic_sds_port_default_link_down_handler,
|
|
|
.start_io_handler = scic_sds_port_default_start_io_handler,
|
|
|
.complete_io_handler = scic_sds_port_stopping_state_complete_io_handler
|
|
|
},
|
|
|
[SCI_BASE_PORT_STATE_READY] = {
|
|
|
- .frame_handler = scic_sds_port_default_frame_handler,
|
|
|
- .event_handler = scic_sds_port_default_event_handler,
|
|
|
.link_up_handler = scic_sds_port_default_link_up_handler,
|
|
|
.link_down_handler = scic_sds_port_default_link_down_handler,
|
|
|
.start_io_handler = scic_sds_port_default_start_io_handler,
|
|
|
.complete_io_handler = scic_sds_port_general_complete_io_handler
|
|
|
},
|
|
|
[SCIC_SDS_PORT_READY_SUBSTATE_WAITING] = {
|
|
|
- .frame_handler = scic_sds_port_default_frame_handler,
|
|
|
- .event_handler = scic_sds_port_default_event_handler,
|
|
|
.link_up_handler = scic_sds_port_ready_waiting_substate_link_up_handler,
|
|
|
.link_down_handler = scic_sds_port_default_link_down_handler,
|
|
|
.start_io_handler = scic_sds_port_ready_waiting_substate_start_io_handler,
|
|
|
.complete_io_handler = scic_sds_port_ready_substate_complete_io_handler,
|
|
|
},
|
|
|
[SCIC_SDS_PORT_READY_SUBSTATE_OPERATIONAL] = {
|
|
|
- .frame_handler = scic_sds_port_default_frame_handler,
|
|
|
- .event_handler = scic_sds_port_default_event_handler,
|
|
|
.link_up_handler = scic_sds_port_ready_operational_substate_link_up_handler,
|
|
|
.link_down_handler = scic_sds_port_ready_operational_substate_link_down_handler,
|
|
|
.start_io_handler = scic_sds_port_ready_operational_substate_start_io_handler,
|
|
|
.complete_io_handler = scic_sds_port_ready_substate_complete_io_handler,
|
|
|
},
|
|
|
[SCIC_SDS_PORT_READY_SUBSTATE_CONFIGURING] = {
|
|
|
- .frame_handler = scic_sds_port_default_frame_handler,
|
|
|
- .event_handler = scic_sds_port_default_event_handler,
|
|
|
.link_up_handler = scic_sds_port_default_link_up_handler,
|
|
|
.link_down_handler = scic_sds_port_default_link_down_handler,
|
|
|
.start_io_handler = scic_sds_port_default_start_io_handler,
|
|
|
.complete_io_handler = scic_sds_port_ready_configuring_substate_complete_io_handler
|
|
|
},
|
|
|
[SCI_BASE_PORT_STATE_RESETTING] = {
|
|
|
- .frame_handler = scic_sds_port_default_frame_handler,
|
|
|
- .event_handler = scic_sds_port_default_event_handler,
|
|
|
.link_up_handler = scic_sds_port_reset_state_link_up_handler,
|
|
|
.link_down_handler = scic_sds_port_reset_state_link_down_handler,
|
|
|
.start_io_handler = scic_sds_port_default_start_io_handler,
|
|
|
.complete_io_handler = scic_sds_port_general_complete_io_handler
|
|
|
},
|
|
|
[SCI_BASE_PORT_STATE_FAILED] = {
|
|
|
- .frame_handler = scic_sds_port_default_frame_handler,
|
|
|
- .event_handler = scic_sds_port_default_event_handler,
|
|
|
.link_up_handler = scic_sds_port_default_link_up_handler,
|
|
|
.link_down_handler = scic_sds_port_default_link_down_handler,
|
|
|
.start_io_handler = scic_sds_port_default_start_io_handler,
|