omap: iommu-load cam register before flushing the entry

The flush_iotlb_page is not loading the cam register before flushing
the cam entry. This causes wrong entry to be flushed out from the TLB, and
if the entry happens to be a locked TLB entry it would lead to MMU faults.

The fix is to load the cam register with the address to be flushed before
flushing the TLB entry.

Signed-off-by: Hari Kanigeri <h-kanigeri2@ti.com>
Acked-by: Hiroshi DOYU <Hiroshi.DOYU@nokia.com>
Signed-off-by: Tony Lindgren <tony@atomide.com>
Hari Kanigeri преди 15 години
родител
ревизия
0fa035e523
променени са 1 файла, в които са добавени 1 реда и са изтрити 0 реда
  1. 1 0
      arch/arm/plat-omap/iommu.c

+ 1 - 0
arch/arm/plat-omap/iommu.c

@@ -320,6 +320,7 @@ void flush_iotlb_page(struct iommu *obj, u32 da)
 		if ((start <= da) && (da < start + bytes)) {
 			dev_dbg(obj->dev, "%s: %08x<=%08x(%x)\n",
 				__func__, start, da, bytes);
+			iotlb_load_cr(obj, &cr);
 			iommu_write_reg(obj, 1, MMU_FLUSH_ENTRY);
 		}
 	}