regulator: palmas: Fix off-by-one for ramp_delay and register value mapping

Datasheet says:
Time Step (TSTEP) selection, when changing the output voltage, the new value is
reached through successive voltage steps (if not bypassed). The equivalent
programmable slew rate of the output voltage is:

TSTEP[1:0]: 00 Jump (no slope control)
TSTEP[1:0]: 01 10mV/us
TSTEP[1:0]: 10 5mV/us (default)
TSTEP[1:0]: 11 2.5mV/us

Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Axel Lin 12 years ago
parent
commit
0ea34b5786
1 changed files with 2 additions and 2 deletions
  1. 2 2
      drivers/regulator/palmas-regulator.c

+ 2 - 2
drivers/regulator/palmas-regulator.c

@@ -447,9 +447,9 @@ static int palmas_smps_set_ramp_delay(struct regulator_dev *rdev,
 
 	if (ramp_delay <= 0)
 		reg = 0;
-	else if (ramp_delay < 2500)
+	else if (ramp_delay <= 2500)
 		reg = 3;
-	else if (ramp_delay < 5000)
+	else if (ramp_delay <= 5000)
 		reg = 2;
 	else
 		reg = 1;