@@ -169,6 +169,7 @@ lm75_probe(struct i2c_client *client, const struct i2c_device_id *id)
|
|
|
int status;
|
|
|
u8 set_mask, clr_mask;
|
|
|
int new;
|
|
|
+ enum lm75_type kind = id->driver_data;
|
|
|
|
|
|
if (!i2c_check_functionality(client->adapter,
|
|
|
I2C_FUNC_SMBUS_BYTE_DATA | I2C_FUNC_SMBUS_WORD_DATA))
|
|
@@ -187,30 +188,59 @@ lm75_probe(struct i2c_client *client, const struct i2c_device_id *id)
|
|
|
set_mask = 0;
|
|
|
clr_mask = LM75_SHUTDOWN; /* continuous conversions */
|
|
|
|
|
|
- switch (id->driver_data) {
|
|
|
+ switch (kind) {
|
|
|
case adt75:
|
|
|
clr_mask |= 1 << 5; /* not one-shot mode */
|
|
|
+ data->resolution = 12;
|
|
|
+ data->sample_time = HZ / 8;
|
|
|
break;
|
|
|
case ds1775:
|
|
|
case ds75:
|
|
|
case stds75:
|
|
|
- clr_mask |= 3 << 5; /* 9-bit mode */
|
|
|
+ clr_mask |= 3 << 5;
|
|
|
+ set_mask |= 2 << 5; /* 11-bit mode */
|
|
|
+ data->resolution = 11;
|
|
|
+ data->sample_time = HZ;
|
|
|
+ break;
|
|
|
+ case lm75:
|
|
|
+ case lm75a:
|
|
|
+ data->resolution = 9;
|
|
|
+ data->sample_time = HZ / 2;
|
|
|
+ break;
|
|
|
+ case max6625:
|
|
|
+ data->resolution = 9;
|
|
|
+ data->sample_time = HZ / 4;
|
|
|
+ break;
|
|
|
+ case max6626:
|
|
|
+ data->resolution = 12;
|
|
|
+ data->resolution_limits = 9;
|
|
|
+ data->sample_time = HZ / 4;
|
|
|
+ break;
|
|
|
+ case tcn75:
|
|
|
+ data->resolution = 9;
|
|
|
+ data->sample_time = HZ / 8;
|
|
|
break;
|
|
|
case mcp980x:
|
|
|
+ data->resolution_limits = 9;
|
|
|
+ /* fall through */
|
|
|
case tmp100:
|
|
|
case tmp101:
|
|
|
+ set_mask |= 3 << 5; /* 12-bit mode */
|
|
|
+ data->resolution = 12;
|
|
|
+ data->sample_time = HZ;
|
|
|
+ clr_mask |= 1 << 7; /* not one-shot mode */
|
|
|
+ break;
|
|
|
case tmp105:
|
|
|
case tmp175:
|
|
|
case tmp275:
|
|
|
case tmp75:
|
|
|
- clr_mask |= 3 << 5; /* 9-bit mode */
|
|
|
+ set_mask |= 3 << 5; /* 12-bit mode */
|
|
|
clr_mask |= 1 << 7; /* not one-shot mode */
|
|
|
+ data->resolution = 12;
|
|
|
+ data->sample_time = HZ / 2;
|
|
|
break;
|
|
|
}
|
|
|
|
|
|
- data->resolution = 9;
|
|
|
- data->sample_time = HZ + HZ / 2;
|
|
|
-
|
|
|
/* configure as specified */
|
|
|
status = lm75_read_value(client, LM75_REG_CONF);
|
|
|
if (status < 0) {
|