Selaa lähdekoodia

wl1271: Increase timeout for command event waiting

Incresed the timeout value for command complete event waiting from 100
ms to 750 ms. In some rare cases it can take about 600 ms before
complete event for join command is received. This is most propably
caused by the firmware being busy with scanning related activities.

Signed-off-by: Teemu Paasikivi <ext-teemu.3.paasikivi@nokia.com>
Reviewed-by: Juuso Oikarinen <juuso.oikarinen@nokia.com>
Signed-off-by: Luciano Coelho <luciano.coelho@nokia.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
Teemu Paasikivi 15 vuotta sitten
vanhempi
commit
0cbb103439
1 muutettua tiedostoa jossa 1 lisäystä ja 1 poistoa
  1. 1 1
      drivers/net/wireless/wl12xx/wl1271_cmd.h

+ 1 - 1
drivers/net/wireless/wl12xx/wl1271_cmd.h

@@ -129,7 +129,7 @@ enum cmd_templ {
 /* unit ms */
 #define WL1271_COMMAND_TIMEOUT     2000
 #define WL1271_CMD_TEMPL_MAX_SIZE  252
-#define WL1271_EVENT_TIMEOUT       100
+#define WL1271_EVENT_TIMEOUT       750
 
 struct wl1271_cmd_header {
 	__le16 id;