mmc: msm_sdcc: Check for only DATA_END interrupt to end a request

The current code checks for both DATA_END and DATA_BLK_END bits in
MCI_STATUS register and ends a request only if both are set at a time.
The hardware doesn't always set DATA_BLK_END when DATA_END is set.
But DATA_END status itself is sufficient condition from hardware that
data transfer is done and hence, check for only DATA_END interrupt in
software to end a request.

Signed-off-by: Sahitya Tummala <stummala@codeaurora.org>
Signed-off-by: David Brown <davidb@codeaurora.org>
Sahitya Tummala 14 gadi atpakaļ
vecāks
revīzija
0c521ccbd0
2 mainītis faili ar 4 papildinājumiem un 12 dzēšanām
  1. 4 11
      drivers/mmc/host/msm_sdcc.c
  2. 0 1
      drivers/mmc/host/msm_sdcc.h

+ 4 - 11
drivers/mmc/host/msm_sdcc.c

@@ -190,7 +190,7 @@ static void
 msmsdcc_stop_data(struct msmsdcc_host *host)
 {
 	host->curr.data = NULL;
-	host->curr.got_dataend = host->curr.got_datablkend = 0;
+	host->curr.got_dataend = 0;
 }
 
 uint32_t msmsdcc_fifo_addr(struct msmsdcc_host *host)
@@ -277,8 +277,7 @@ msmsdcc_dma_complete_tlet(unsigned long data)
 	host->dma.sg = NULL;
 	host->dma.busy = 0;
 
-	if ((host->curr.got_dataend && host->curr.got_datablkend)
-	     || mrq->data->error) {
+	if (host->curr.got_dataend || mrq->data->error) {
 
 		/*
 		 * If we've already gotten our DATAEND / DATABLKEND
@@ -506,7 +505,6 @@ msmsdcc_start_data(struct msmsdcc_host *host, struct mmc_data *data,
 	host->curr.xfer_remain = host->curr.xfer_size;
 	host->curr.data_xfered = 0;
 	host->curr.got_dataend = 0;
-	host->curr.got_datablkend = 0;
 
 	memset(&host->pio, 0, sizeof(host->pio));
 
@@ -827,14 +825,10 @@ msmsdcc_handle_irq_data(struct msmsdcc_host *host, u32 status,
 	if (!host->curr.got_dataend && (status & MCI_DATAEND))
 		host->curr.got_dataend = 1;
 
-	if (!host->curr.got_datablkend && (status & MCI_DATABLOCKEND))
-		host->curr.got_datablkend = 1;
-
 	/*
 	 * If DMA is still in progress, we complete via the completion handler
 	 */
-	if (host->curr.got_dataend && host->curr.got_datablkend &&
-	    !host->dma.busy) {
+	if (host->curr.got_dataend && !host->dma.busy) {
 		/*
 		 * There appears to be an issue in the controller where
 		 * if you request a small block transfer (< fifo size),
@@ -871,8 +865,7 @@ msmsdcc_irq(int irq, void *dev_id)
 
 	do {
 		status = msmsdcc_readl(host, MMCISTATUS);
-		status &= (msmsdcc_readl(host, MMCIMASK0) |
-					      MCI_DATABLOCKENDMASK);
+		status &= msmsdcc_readl(host, MMCIMASK0);
 		msmsdcc_writel(host, status, MMCICLEAR);
 
 		if (status & MCI_SDIOINTR)

+ 0 - 1
drivers/mmc/host/msm_sdcc.h

@@ -190,7 +190,6 @@ struct msmsdcc_curr_req {
 	unsigned int		xfer_remain;	/* Bytes remaining to send */
 	unsigned int		data_xfered;	/* Bytes acked by BLKEND irq */
 	int			got_dataend;
-	int			got_datablkend;
 	int			user_pages;
 };