@@ -502,10 +502,26 @@ static int cx22702_read_signal_strength(struct dvb_frontend *fe,
|
|
|
u16 *signal_strength)
|
|
|
{
|
|
|
struct cx22702_state *state = fe->demodulator_priv;
|
|
|
+ u8 reg23;
|
|
|
|
|
|
- u16 rs_ber;
|
|
|
- rs_ber = cx22702_readreg(state, 0x23);
|
|
|
- *signal_strength = (rs_ber << 8) | rs_ber;
|
|
|
+ /*
|
|
|
+ * Experience suggests that the strength signal register works as
|
|
|
+ * follows:
|
|
|
+ * - In the absence of signal, value is 0xff.
|
|
|
+ * - In the presence of a weak signal, bit 7 is set, not sure what
|
|
|
+ * the lower 7 bits mean.
|
|
|
+ * - In the presence of a strong signal, the register holds a 7-bit
|
|
|
+ * value (bit 7 is cleared), with greater values standing for
|
|
|
+ * weaker signals.
|
|
|
+ */
|
|
|
+ reg23 = cx22702_readreg(state, 0x23);
|
|
|
+ if (reg23 & 0x80) {
|
|
|
+ *signal_strength = 0;
|
|
|
+ } else {
|
|
|
+ reg23 = ~reg23 & 0x7f;
|
|
|
+ /* Scale to 16 bit */
|
|
|
+ *signal_strength = (reg23 << 9) | (reg23 << 2) | (reg23 >> 5);
|
|
|
+ }
|
|
|
|
|
|
return 0;
|
|
|
}
|