Browse Source

thermal: kirkwood: Fix valid check for thermal register

The correct value is obtain by first shifting the register by the offset,
later applying the valid mask and finally invert the result.
This check was lacking an extra parenthesis to be strictly correct.

Signed-off-by: Ezequiel Garcia <ezequiel.garcia@free-electrons.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Ezequiel Garcia 12 years ago
parent
commit
02519d3397
1 changed files with 2 additions and 2 deletions
  1. 2 2
      drivers/thermal/kirkwood_thermal.c

+ 2 - 2
drivers/thermal/kirkwood_thermal.c

@@ -41,8 +41,8 @@ static int kirkwood_get_temp(struct thermal_zone_device *thermal,
 	reg = readl_relaxed(priv->sensor);
 
 	/* Valid check */
-	if (!(reg >> KIRKWOOD_THERMAL_VALID_OFFSET) &
-	    KIRKWOOD_THERMAL_VALID_MASK) {
+	if (!((reg >> KIRKWOOD_THERMAL_VALID_OFFSET) &
+	    KIRKWOOD_THERMAL_VALID_MASK)) {
 		dev_err(&thermal->device,
 			"Temperature sensor reading not valid\n");
 		return -EIO;